Standards
During my revisions, I took into consideration the following standards:
- Excerpt -
14/2004. (IV.19.) FMM decree.
28/2011. (IX.6.) BM decree (Nationwide Fireprotection code)
8/1981. (XII. 27.) IpM decree about the Communal and apartman buildings’ touchprotection code.
9/2008. (II. 22.) ÖTM decree
about the Nationwide Fireprotection publication
2/2002. (I.23.) BM decree
Fireprotection and civil defense technical requirements
35/1996. (XII.29.) BM decree
Nationwide FireProtection decree publication ( OTSZ )
MSZ 2364 Standard series
At the most the 1000 V voltage strongpowered electrical equipment creation
MSZ 4852:1977
Eletric equipment insulation resistance measurements
MSZ 4851-1-6 Standard series
Touchprotection revision methods
ME-04-115:1982
Creating the equal potential’ s network
ME-04-124:1979
Using ferro-concrete foundation for the purpose of grounding
8/1981. (XII.27.) IpM rendelet
MSZ EN 1585:2001
Strong Powered plants rules and regulations.
MSZ 13207:2000
MSZ 1600 1-16. Standard Series
Safety and security rules for electric equipments, that are not stronger than 1000 Volts,
MSZ 172-1:1986
Touchprotection rules and regulations
MSZ 172-1:1986/1M(1989)
Touchprotection rules and regulations ( modifications )
MSZ 10900:1970 +1 M:1986
Those strong powered electric equipments that are not above 1000 Volts
periodic revisions
MSZ 453:1987
Safety tablets for strong powered electric equipments
MSZ 2064-2:1998
Basic principles of electric equipments . Electric structures choosing and their fixing.
MSZ EN 60529:2001
Safety degrees ( IP code ) provided by the cover eletric equipmentss
MSZ 595 Standard Series
Fireprotection of buildings
MSZ 447:1998
connected to Public small powered network
MSZ EN 50110-1…2:1999
Running electric equipments
MSZ 1:2002
Standardized eletric powers
MSZ 171-1:1984
Electric equipment’s common safety and security requirements. Touchprotection classification.
LAWS require the Touchprotection Revisions !
The Minister of the Employment policy and labor ministry have issued a long awaited decree, in which he has ordered the Touchprotection fitters revisions and standardized revisions to be performed systematically. It was very timely to order this systematic revision, because since the mandatory standards have been eliminated on December, 2001. no one, not the owners and not the users were required to perform these revisions any more. The detailed standards were revoked as well in February, 2003. The 22/2005. (XII.21.) FMM decree has modified the minimal required levels of the manual worktools and their usage in the 14/2004. (IV.19.) FMM decree in its 2nd paragraph has defined the repairman’s revision A 22/2005. (XII.21.) FMM and then states the following :
„5/A.§ (1) The employer takes care of the small powered electric equipment’s touchprotection periodic revisions and different from the 4-5. §-paragraphs it will take care of the revisions as part of the standardized process.
(2) The revision overview must be done prior to starting the operation and after the enlargement of the touchprotection and repairs, the last repair must be done with the standardized overview.
(3) The periodic revision must be accomplished :
a) monthly revision of the breaker by repairman supervision
b) manual tools and portable safety transformers with annual revisions by repairman supervision
c) 8/1981.(XII. 27.) IpM decree covers the Communal and Building Touchprevention rules stating
other electric equipment revision must be checked every 6 years
d) on other electric equipments every 3 years,with standardized revision.
As we have mentioned the decree is a stop-gap,but its still just a makeshift solution.
The Touchprotection revisions should be fully and completely finalized – together with several other electric safety themes, will be really completed int he shortly publicized Electric Safety Rulebook ( VBSZ ) for which all profesionnals are waiting for the past 10 years. ( The first version of this VBSZ Electric Safety Rulebook was made in 1995 by the professional experts. )
To remind the reader , the revision of the strong current electric equipments and the so called FireProtection Revision are in the 35/1996 (XII. 29.) BM decree, in the Nationwide FireProtection Decree and the 2/2002 (I. 23.) BM decree ensures depending on the building’s firesafety classification .
Lectored : Kádár Aba Arató Csaba member of MEE
ELEKTROTECHNIKA 2 0 0 6 . 2 . I S S U E .
We look forward to hearing from you with your request for our offer !